High Temperature, Heat Resistant and Thermal Insulating / Molten Metal Splash
Protection EAF & High Current Water Cooled Cable Cover
EAF Cable Cover
Electric Arc Furnace water cooled high-current cables take a beating - protect them with the toughest sleeve available specifically designed to protect against heat, flame, molten splash and slag.

Available in any size.  For sleeve up to approximately 2 inches in diameter, a 0.75" wide velcro closure is used. For sleeves between approximately 2 and 6 inches in diameter, a 1" wide velcro closure is used.  For sleeve above 6 inches wide, a 2" wide velcro is used.

Sewing of the sleeve is performed using a Nomex or Kevlar thread.
Silicone Rubber Coated Fiberglass (fibreglass / glassfibre) Sleeve Withstands Molten Splash & Welding Splatter.  Withstands 500°F / 260°C continuous exposure; 2200°F / 1205°C for periods up to 15 minutes and short flash excursions to 3000°F / 1650°C.

Molten metals simply slide off of the extra heavy duty coating of High-Temperature Silicone Rubber on all of these products (firesleeve), providing excellent burn-through protection.